Rotolavit II-S

Developed to be used in conjunction with the Sysmex PS-10 sample preparation system, the Hettich Rotolavit II-S automates the routine washing steps when preparing blood samples for flow cytometric analysis.

Its modern touch screen enables the simple and rapid input of up to 20 different programs, which can be run on demand. The programs are set up by freely combining modular steps for the different functionalities that can be further customized by adjusting the desired speed and time of centrifugation, decantation, and volume of refilling with washing solution.

Features
  • High processing speed by washing up to 24 samples simultaneously.
  • Customised processes can be generated by combining individual process steps from the following:
    • Fill (dispense saline solution into all tubes in the used rotor)
    • Spin (spin the rotor to pellet cells)
    • Decant (decanting of supernatant)
    • Agit (resuspension of cell pellets by agitation/shaking)
    • Down (short spin to collect droplets at the base of the tubes)
    • Loop (can be applied to automatically repeat previous steps of the process)
    • Check (automatically interrupts the process to allow visual inspection of the samples)
  • The process steps can be individually configured (e.g. change time or speed) by the user and stored in the device.
  • Change acceleration and deceleration to optimize cell viability.
  • The configured process steps are processed automatically by the device.
  • The instrument is used with Sysmex-specific swing out rotors with 12 or 24 sample tube positions, which are also compatible with Sysmex PS-10 sample preparation system.
  • Generation of processes is password protected.
  • Logs information on use of system.
  • Selection of six different operating languages available on the Rotolavit II-S (English, French, German, Spanish, Portuguese and Italian)
Technical Specifications

User-programmable steps

  • Fill (dispense saline solution into all tubes in the used rotor)
  • Spin (spin the rotor to pellet cells)
  • Decant (decanting of supernatant)
  • Agit (resuspension of cell pellets by agitation/shaking)
  • Down (short spin to collect droplets at the base of the tubes)
  • Loop (can be applied to automatically repeat previous steps of the process)
  • Check (automatically interrupts the process to allow visual inspection of the samples)

Dispense volumes

0.1 ml to 4 ml per sample tube

Accuracy

Sample fill volume ± 15%

Speed

Up to 3500 rpm

Force

Up to 1438 RFC

Kinetic energy, max.

250 Nm

Suitable rotors

12 position swing out rotor,  24 position swing out rotor

Sample Tube capacity

Up to 12 or 24 tubes (depending on rotor used)

Compatible sample tubes

  • 12 mm x 75 mm
  • 13 mm x 75 mm
  • glass- or plastic-types

Dimensions

H x W x D

280 mm x 330 mm x 480 mm (closed lid)

Height with open lid: 580 mm

Weight

approx. 24.4 kg

Power requirements

100 to 240 V / 50/60 Hz / 150 W / 144 VA / Fuse: 10 A / 250 V F

 

Contacts
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Egypt LLC

New Cairo 11835, Fifth Settlement –

First District Fifth local area - Building (S5-6)

Egypt

+20225653570

+20225653472

Explore more

PS-10

PS-10

Automated sample preparation for clinical flow cytometry

Details
Sysmex TBNK test system

Sysmex TBNK test system

Reagent system for reliable lymphocyte subset analysis

Details
Copyright © Sysmex Europe SE. All rights reserved.