XN-1000

This is a stand-alone instrument. In its Rerun & Reflex configuration, the XN-1000 offers reproducible result quality in the shortest possible time. By automatically reanalysing samples for which results are considered unreliable, it significantly reduces manual interventions and frees up time and resources. With no compromise on turnaround time. Reagent management is simple too – if you want we can integrate your reagents in the optional analyser wagon.

The XN-1000 can be equipped with all the available diagnostic applications. Depending on what is installed, the XN Rerun & Reflex performs a range of rule-based tests. The positive samples are fed into extended measurement automatically. Extended measurement is only performed if it adds additional diagnostic value.

While the XN-1000 is a stand-alone system, optional software can still make it uniquely flexible. It can be networked with other XN solutions at other locations. Think of individual systems for measuring body fluids on neurology wards. Or transfusion centres. And thanks to our remote services, we can together define levels of support quality, guaranteed service response times and ensure maximum system uptime.

Technical Specifications
Measurement principles WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin
Aspiration volume  88 µL in whole blood (WB) mode and body fluid (BF) mode
Throughput    up to 100 samples/h
Quality control material XN Check (three levels) and XN Check BF (two levels)
Parameters    XN-CBC (always with NRBC) & XN-DIFF (always with IG)

Whole Blood   
WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#

With RET (optional)       
RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O

With PLT-F (optional)   
PLT-F, IPF, IPF#

With WPC (optional)   
Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#

XN Stem Cells licence    
HPC%, HPC#

Body Fluids with XN-BF   
WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#
(optional)
Configurations XN-1000 [DIFF]
XN-1000 [WPC]

 

Contacts
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Egypt LLC

New Cairo 11835, Fifth Settlement –

First District Fifth local area - Building (S5-6)

Egypt

+20225653570

+20225653472

Documents

Product documents

Safety data sheets

Regulatory Documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

XN-2000

XN-2000

A perfect pair for basic and extended testing

Details
XN-9000

XN-9000

The new standard in haematology

Details
XN-1000V

XN-1000V

It’s time for veterinary excellence

Details
Copyright © Sysmex Europe SE. All rights reserved.