XN-1000V

With the Sysmex XN-V Series, you can deliver diagnostic results with the highest quality and value. Both the XN-1000V and XN-2000V are efficient, offer consistently reliable and secure results and can be customised or upscaled whenever you need.

Since diagnostic information needs to be provided for a wide range of species, we have predefined 19 commonly tested animal species for you. Additionally, you can define your own settings as needed, either for research purposes and/or to provide additional diagnostic value. Online quality control ensures that your new analyser is reliable and efficient. An optical platelet count, reticulocyte parameters and body fluid analysis offer additional diagnostic insight where needed.

Features

Non-mammalian analysis

Analysis parameters  Channel
WBC  PLT-F channel 
RBC PLT-F channel 
H-RBC (haemolysed RBC)  PLT-F channel 
HGB SLS-Hemoglobin method 
HCT RBC particle size distribution 
MCV RBC particle size distribution 
MCH RBC particle size distribution 
MCHC RBC particle size distribution 
PLT PLT-F channel 
RDW-SD  RBC particle size distribution
RDW-CV RBC particle size distribution
RBC-O RET channel 
Technical Specifications
Species Mouse, rat, dog, NHP, rabbit, cat, horse, cattle, pig, mini pig, Guinea pig, gerbil, camel, dolphin, marmoset, ferret, sheep, goat, hamster, bird
Strain species Mouse 1-15, rat 1-10, NHP 1-10, rabbit 1-5, dog 1-5, pig 1-5
Customisable free species settings Free 1-99
Measurement modes Whole blood (WB) mode
Low aspiration volume (LA) mode
Low WBC (LW) mode
Pre-diluted (PD) mode
Body fluid (BF) mode**
Aspiration volume 88 µL in WB and BF measurement modes
70 µL in PD measurement mode
50 µL in LA measurement mode
Throughput XN-1000V
100 samples/h in WB mode (CBC+DIFF)
83 samples/h in WB mode (CBC+DIFF+RET**)
40 samples/h in BF mode**
Technologies Fluorescence flow cytometry
Hydrodynamically focused impedance measurement
Cyanide-free SLS haemoglobin method
Adaptive cluster analysis system (ACAS) and special three-dimensional shape recognition analysis of each WBC subpopulation
Quality control XN CHECK
XN CHECK BF**
Calibrator XN CAL
Standard parameters XN-CBC
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV,
PDW, MPV, P-LCR, PCT, NRBC %, NRBC#, MicroR*, MacroR*

XN-DIFF
NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#
Optional parameters

RET
RET%, RET#, PLT-O, IRF, LFR, MFR, HFR, RET-He , HYPO-He*, HYPER-He*

XN-BF
WBC-BF, RBC-BF, PMN%, PMN#, MN%, MN#, TC-BF#, RBC-BF2*

PLT-F 
PLT-F1, IPF1, WBC2, RBC2,,H-RBC*,2, PLT2 

Configurations XN-1000V, XN-2000V.
Both models can be equipped with individually chosen clinical insight applications RET and/or XN-BF.
 
Data storage 30,000 samples
Supported sample tubes Regular tubes, raised bottom tubes (RBT), micro collection tubes
Sample security Duplicate barcode reading
Reagent management Available
User management Available
Customisable rules Available
Customisable software Available

** optionally available
*parameters hidden by default

1Not analysed in LA mode 
2Only for bird species analysis

Contacts
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Egypt LLC

New Cairo 11835, Fifth Settlement –

First District Fifth local area - Building (S5-6)

Egypt

+20225653570

+20225653472

Training

XN-V Series basic online training

Learning objectives

This course will provide solid basic knowledge on how to operate the XN-V Series, including start-up/shutdown, analysis and basic maintenance. You will be able to determine which species are analysed, choose your workflow, and manage your results as you require.

sysmex-academy.com/learn/xn-v-series-basic-online-training

 

Documents

Product documents

Safety data sheets

Regulatory Documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

XN-2000v

XN-2000v

It’s time for veterinary excellence

Details
Copyright © Sysmex Europe SE. All rights reserved.